Canary-Zero™ reports the presence of nerve agents or blister agents in air every 20 seconds. The entry price for this chemical sensor system enables large-scale deployment for distributed chemical sensor networks. Its low mass makes it a superior solution for UAV and UGV payloads.

Canary-Three™ identifies chemical weapons by name. For instance, if both sarin (GB) and soman (GD) are released, Canary-Three™ will report both chemicals and their relative concentrations. A full analysis of air samples takes about two minutes. An option for Canary-Three™ includes Intelligent Sampling, which automatically adjusts collection times to ambient conditions. At high concentrations, collection times are short to provide answers quickly. This option also includes the fast alarm feature of Canary-ZeroTM.

FROG-4000™ is specifically designed for detection and analysis of VOCs in water. The system combines all the elements of a bench-top purge and trap–GC/PID in a handheld instrument. It is ideal for field applications.
Canary-Three™
Micro GC Separations with Smart Sample Collection

Canary-Three™ is designed to distinguish target analytes from background chemicals and each other for identification and quantitative analysis in two minutes.

The system has an integrated micro gas chromatography column that separates compounds for individual detection by a surface acoustic wave detector (SAW). The system also has a selective micro preconcentrator (collector) that ignores background chemicals during sampling.


Canary Three Chemical Detector Chemical Sensor

Canary-Three™ can be used in the field as a point and analyze instrument, or may be packaged for unmanned uses or emplaced in a sensor network for continuous monitoring.
Canary Three Chemical Detector Chemical Sensor
Canary-Three™
An option for Canary-Three™ is the sensor industry’s first handheld, intelligent gas sensor.

If the ambient concentration of a target analyte is high, Canary-Three™ autonomously determines a short sample collection time. For low concentrations, it will autonomously collect a larger sample volume.

Intelligent sample collection has many benefits. It increases detection range and assures optimal performance at any concentration. It also prevents the system from being overwhelmed by high concentrations. More importantly, the system provides results fastest when concentrations (and dangers) are greatest.

The system features selective chemical collection so that interfering chemicals are ignored, a rapid screening detector for results within seconds, and a micro GC column to separate and uniquely identify target chemicals.

Canary Three Chemical Detector Chemical Sensor

The Canary-Three™ Smart Sampling option employs dual detectors. One for rapid screening, and one coupled with a micro-GC for detailed analysis.

Chemical Capabilities:
  • Chemical Weapons
  • Pesticides
  • Fragrances
  • Flavorants
  • Applications:
  • Homeland Security
  • Defense
  • Hazmat
  • First Response
  • Agriculture
  • Food Safety

  • Canary Three Chemical Sensor Chemical Detector
    Separation of GB, DMMP, GD, and GF in the same analysis cycle
    The graph on the left shows the results of collection, separation and detection of five different chemicals simultaneously. Sarin, DMMP, Soman, Tabun, and Cyclosarin are distinguished from one another in the same two minute cycle.
     
    Canary Three Chemical Sensor Chemical Detector
    Detection of exotetrahydrodicyclopentadiene,
    commonly called JP-10
    This data is from the detection of JP-10 in under two minutes by the Canary-Three™ system. JP-10 detection is essential for worker safety.
     
    Canary Three Chemical Sensor Chemical Detector
    Demonstration of Intelligent Sampling
    The diagram on the left demonstrates Canary-Three™ intelligent collection. The top trace shows how the system responds to a concentration of 180 ppb. The lower trace shows the system automatically reducing the sample collection time when the concentration is 10 times higher.


    Features and Specifications
    Dimensions
    12 x 6 x 4 inches
    Weight
    1200 g (2.4 lbs.)
    Power
    Four hours on rechargeable lithium polymer batteries or external 9V, 2A power supply
    Computer Interface
    Standard RS-232 port
    Display
    2.1 x .75 inch LCD
    Cycle Time
    Rapid Screening: 8 Seconds
    GC Analysis: 2 Minutes
    Carrier Gas
    None, ambient air is carrier gas